# Sodural - Electrical Power Engineering & Public Physics MCP Server (SI) > **Bilingual Discovery File (EN / FR)** for LLMs, AI coding agents, and engineering search tools. > Sodural provides a browser-native LV/MV/HV electrical network engineering suite (zero-upload client RAM execution) and a **zero-authentication public Model Context Protocol (MCP) & OpenAPI 3.1 REST gateway** exposing **29 deterministic SI electrical physics calculators**, **8 guided engineering prompts**, and **3 governance resources**. ## Quick Links & Machine-Readable Endpoints - **Web Platform**: https://sodural.com (Mirror: https://solufuse.com) - **Free Browser Tier 0 Calculator (No Login)**: https://sodural.com/calculatrice-htb-hta (FR) | https://sodural.com/high-voltage-mcp-calculator (EN) - **Public Brain MCP Endpoint (No Auth / N0 Tier / v5.2.0 / Streamable HTTP JSON-RPC 2.0)**: https://sodural.com/mcp/brain - **Gemini CLI Quick Install**: `gemini extensions install https://github.com/solufuse/sodural-electrical-mcp` or `gemini mcp add --transport http sodural-electrotech-brain https://sodural.com/mcp/brain` - **Unified MCP Endpoint (OAuth 2.1 PKCE + Public Demo Pairing `sdrl_demo`)**: https://sodural.com/mcp - **Public Brain OpenAPI 3.1 Specification**: https://sodural.com/api/brain/openapi.json - **Unified REST OpenAPI 3.1 Specification**: https://sodural.com/api/openapi.json - **Public Brain Health Check**: https://sodural.com/mcp/brain/health - **Full Technical Context for LLMs**: https://sodural.com/llms-full.txt - **MCP Discovery Manifest**: https://sodural.com/.well-known/mcp.json - **Glama Connector Claim**: https://sodural.com/.well-known/glama.json - **Public GitHub MCP Showcase Kit**: https://github.com/solufuse/sodural-electrical-mcp - **Platform Status & Endpoints Directory**: https://sodural.com/status - **Engineering Curriculum & Documentation**: https://sodural.com/formation | https://sodural.com/docs ## Connect an AI Agent in 3 Lines (Zero Auth) Streamable HTTP MCP clients (Claude, Cursor, VS Code Copilot, Gemini CLI, Antigravity): ```json { "mcpServers": { "sodural-electrotech-brain": { "url": "https://sodural.com/mcp/brain" } } } ``` Or query via REST API: `GET https://sodural.com/api/brain/tools` and `POST https://sodural.com/api/brain/tools/`. ## 29 Public SI Electrical Physics Tools (`/mcp/brain`) ### 1. Formulas & Equations (`formulas_and_equations`) - `brain_explain_formula`: Symbolic electrical and geotechnical physics equations with SI variables and physical validity bounds. ### 2. LV & MV Sizing (`lv_mv_sizing`) - `brain_calc_lv_feeder_physics`: LV feeder cross-section, corrected ampacity `Iz`, voltage drop `dU%`, fault-loop clearing impedance `Zs`, and adiabatic thermal limit. - `brain_calc_mv_delivery_physics`: MV/LV electrical delivery substation model (`1 < Un <= 33 kV`, `<= 630 A`), metering thresholds, bay selection, interlocks, and earthing balance. - `brain_calc_hta_cable_cyclic`: Underground MV/HV cable radial thermal resistances `T1..T4`, cyclic overload factor `M` via `-Ei(-x)`, non-adiabatic short-circuit limit, and induced sheath bonding voltages (SVL). - `brain_calc_mv_switchgear_lineup_sizing`: Multi-transformer MV switchroom cubicle inventory (`1..10` units up to `600 MVA`, `15-63 kV`), incomer splitting factor `k_split`, busbar/feeder current margins, and symmetrical fault withstand. - `brain_calc_underground_hv_cable_pulling`: Underground HV polymer duct bank sizing (`63-400 kV`), static/dynamic bending radii (`15xD`/`20xD`), capstan pulling force, radial sidewall bearing pressure, and cross-bonded/single-point screen voltages. ### 3. Short-Circuit, Earthing & TRV (`short_circuit_earthing_trv`) - `brain_calc_thermal_equivalent_physics`: RL transient peak factor `kappa`, peak current `ip`, Joule decrement factors `m/n`, thermal equivalent `Ith`, breaker margin, and recovery envelope. - `brain_calc_earthing_lightning_trv`: Earth split factor `rf`, earth potential rise `EPR`, human step/touch safety attenuation, adiabatic copper/steel earthing conductor sizing, rolling-sphere lightning shielding, surge arrester coordination, and TRV envelope. - `brain_calc_bpn_ner`: Neutral Earthing Reactor (BPN / NER) sizing from feeder zero-sequence capacitive return `3Ic0`, neutral impedance `Zn`, `51N` anti-sympathy floor, and insulation levels. - `brain_calc_impedance_tolerance`: Transformer short-circuit impedance `Ucc` tolerance bounds (`+/-10%`), linear thermal resistance scaling `R(theta)` (`20 C` to `90 C`), and branch fault sensitivity. - `brain_solve_topology_whitebox_physics`: Multi-bus `Z_bus` symmetrical-component short-circuit (methods A/B/C) and Newton-Raphson AC power flow with OLTC tap regulation. - `brain_calc_hv_substation_grid_compliance`: HV substation (`63-400 kV`) air-density altitude scaling, phase/earth clearances (`Dm`, `Dp`, `Dms`), specific creepage (USCD), ZnO arrester margins, per-unit `U/f/Q` envelope, Biot-Savart busbar electrodynamics, two-layer soil earthing, lightning interception, toroidal CT conduit check, and `48/125 Vdc` auxiliaries. ### 4. Transformers & Protection (`transformers_and_protection`) - `brain_calc_transformer_ecodesign_dga`: Transformer no-load/load losses, Peak Efficiency Index (PEI), 30-year TCO NPV, Maekawa acoustic diffraction, dielectric withstand, and Duval Triangle 1 DGA. - `brain_calc_transformer_inrush`: Cold-load magnetizing inrush decay, thermal damage envelopes, adiabatic cable curves, fuse bands, LSIG trip curves, and capacitor/IBR markers. - `brain_calc_selectivity_tcc`: Inverse-time overcurrent relay coordination curves, analytical TMS solving, two-relay grading margins over `[ikMin, ikMax]`, and switchboard thermal withstand. - `brain_audit_protection_physics`: Chronometric grading budget, CT transient flux `Ktd`/`Eal` & real-burden `ALF`, ANSI 49 thermal equilibrium, genset decrement, BPN limits, compensated/wattmetric earth faults, `67Q/Z2`, grid decoupling, `87T`/`64REF`, fuse-switch transfer, MV motor plan, and logic selectivity. - `brain_calc_hv_protection_21_87t`: HV distance zones (`Z1-Z4`, `kZ0`, load/arc resistance checks), protectability matrix, `87T` differential bias under OLTC (`2W/3W`), and parallel incomers. - `brain_calc_homopolar_67n`: MV zero-sequence capacitive current `3Ic0`, `51N` sympathy-vs-sensitivity corridor, directional `67N` polar RCA sectors, and BPN topology. - `brain_calc_arc_flash_ct_comtrade`: Enclosure arc-flash incident energy and thermal safety boundary, RK4 nonlinear CT saturation integration, asymmetric fault waveforms, and oscillographic record generation/parsing. ### 5. Power Quality & Varmetric (`power_quality_varmetric`) - `brain_calc_power_harmonics`: Harmonic spectrum `THDi`/`TDD`/`THDu`, transformer eddy-current K-factor/`F_HL` derating, detuned RLC resonance scan, and 3-winding harmonic star model. - `brain_calc_reactive_varmetric`: PCC varmetric balance `tan(phi)` across 10-100% load, capacitor-bank `L_choc` switching transients, synchronous generator `P-Q` capability circles, and 3-winding `dU/dQ` sensitivity. ### 6. Reliability & Critical Auxiliaries (`reliability_critical_auxiliaries`) - `brain_calc_system_reliability`: Markov availability, failure frequency, annual downtime hours, nines index, and Value of Lost Load (VoLL) for series, parallel, open-loop, and k-out-of-n topologies. - `brain_calc_critical_power_safety`: Critical power & safety physics: genset altitude derating, UPS/STS transfer, Faraday `H2` battery room dilution airflow, cable separation coupling, oil retention pit volume, and facility PUE/REF metrics. - `brain_convert_electrotech_units`: Exact SI unit conversion and auto-scaling (`VA/kVA/MVA`, `W/kW/MW`, `var/kvar/Mvar`, `A/kA`, `V/kV`, `mOhm/Ohm`). - `brain_calc_civil_concrete_foundation`: Substation concrete foundation sizing & checks: soil bearing capacity, sliding/overturning equilibrium, concrete bending/shear/punching reinforcement, 6-mode tensile anchor cone breakout & blowout, grout lever-arm shear, and durability cover. - `brain_calc_fm_global_fire_smoke_gis`: Substation transformer thermal separation clearances, deluge water-spray hydraulics (`10.2 / 6.1 L/min/m2`), oil/fire-water retention bund volume, thermal/smoke extraction airflow (`vol/h`, `Pa`), aspirating smoke detection coverage, and GIS/MV SF6 room atmosphere & internal-arc overpressure. - `brain_audit_gis_mv_room_air_sf6`: Dedicated metrology & ventilation audit for GIS HV and MV SF6 switchgear rooms: free air volume (`m3`), stratification (`z <= 1.0 m`, cable trench), O2 depletion thresholds (`19.5%` / `17.0%`), `t_95%` purge time, natural/mechanical smoke extraction, arc overpressure (`kPa`), and CO2-equivalent inventory. - `brain_calc_oil_containment_and_drain_hydraulics`: Dielectric oil, deluge spray, and rainfall volume balance with porous stone quenching bed void deduction, Manning-Strickler circular collector pipe sizing, and groundwater Archimedes buoyancy stability. - `brain_calc_heavy_convoy_swept_path_crane`: Heavy transformer multi-axle transport weights, Ackermann turning swept-path corridor width, gate margin check, and outrigger timber mat ground bearing stress (`kPa`). ## Legal Notice & Engineering Responsibility (FR / EN) - **Calculation Aid Only / Aide au calcul uniquement**: All outputs (`calculationTrace`, numbers, margins) are deterministic physical engineering calculation aids. They do not replace applicable standards, project contracts, official design reviews, or sign-off by a qualified electrical/civil engineer. - **Client-Side Privacy**: Browser workbenches execute 100% in local browser memory (`RAM`) with zero network telemetry upload of user studies. `/mcp/brain` is stateless (0 persistent storage).