TIER 0 - OPEN AI BRAIN MCP v5.2.0

Free HV/MV Electrical Calculator & Open AI Brain MCP Server (Tier 0)

Run 29 deterministic SI power system physics calculators free in-browser with zero login, or connect Gemini CLI, Claude, and Cursor via stateless Streamable HTTP at https://sodural.com/mcp/brain.

Quick Install (Gemini CLI & MCP)

gemini extensions install https://github.com/solufuse/sodural-electrical-mcp
gemini mcp add --transport http sodural-electrotech-brain https://sodural.com/mcp/brain

OpenAPI 3.1: https://sodural.com/api/brain/openapi.json | llms.txt

29 Public SI Physics Calculators

Tool IDDomainCalculatorScope
brain_explain_formulaSI Physics Equations & Symbolic DerivationsSI Physics Equation Derivation & VariablesYou pass an equation ID or keyword to inspect its symbolic formula, bounds, and SI units.
brain_calc_lv_feeder_physicsLV Thermal Ampacity & MV Delivery / Cyclic CablesLV Feeder Thermal Ampacity & Voltage Drop PhysicsYou size an LV feeder (cross-section, ampacity Iz, voltage drop dU%, fault loop Zs, adiabatic thermal I2t).
brain_calc_mv_delivery_physicsLV Thermal Ampacity & MV Delivery / Cyclic CablesMV Delivery Substation Physics ModelYou evaluate an MV/LV delivery substation (primary current, power thresholds, switchgear bay sizing, and neutral scheme).
brain_calc_hta_cable_cyclicLV Thermal Ampacity & MV Delivery / Cyclic CablesMV/HV Cables: Thermal Resistance, Cyclic Rating & Sheath BondingYou compute T1..T4 thermal resistances, 24h cyclic factor M, non-adiabatic fault limit, and sheath standing voltages.
brain_calc_mv_switchgear_lineup_sizingLV Thermal Ampacity & MV Delivery / Cyclic CablesMulti-TX MV Switchgear Lineup Sizer (SI)You size parallel MV switchrooms (15 to 63 kV, 1 to 10 transformers up to 600 MVA) against continuous ampacity and symmetrical short-circuit limits.
brain_calc_underground_hv_cable_pullingLV Thermal Ampacity & MV Delivery / Cyclic CablesUnderground HV Duct Bank & Pulling Mechanics (SI)You verify underground HV polymer conduit sizing, static/dynamic bending radii (15xD / 20xD), capstan pulling force, sidewall load, and induced metallic screen voltage.
brain_calc_thermal_equivalent_physicsShort-Circuit, Earthing, Lightning, TRV & HV PhysicsThermal Equivalent Ith, Peak Factor kappa & Recovery EnvelopeYou pass initial symmetrical fault `ikSubPrimeKa`, duration `durationTkSec`, `xrRatio`, and `ratedIcuKa`.
brain_calc_earthing_lightning_trvShort-Circuit, Earthing, Lightning, TRV & HV PhysicsSubstation Earthing, Adiabatic Conductor Sizing, Lightning & TRV PhysicsYou evaluate reduction factor rf, EPR/touch/step voltages, adiabatic earthing conductor cross-section, lightning separation s, or TRV.
brain_calc_bpn_nerShort-Circuit, Earthing, Lightning, TRV & HV PhysicsNeutral Earthing Reactor (NER) Sizing & Capacitive 3Ic0 PhysicsYou supply `voltageKv` and MV `cables` (length in km and zero-sequence capacitance C0 in uF/km).
brain_calc_impedance_toleranceShort-Circuit, Earthing, Lightning, TRV & HV PhysicsUcc Impedance Tolerance Envelope & Thermal Resistance ScalingYou compute Ucc impedance tolerance bounds (±10%) and Cu/Al thermal resistance scaling (20 °C <-> 90 °C).
brain_solve_topology_whitebox_physicsShort-Circuit, Earthing, Lightning, TRV & HV PhysicsWhite-Box Z_bus Short-Circuit & Newton-Raphson Load Flow SolverYou pass bus/branch tables (or default algebraic case) with `mode` and `kappaMethod`.
brain_calc_hv_substation_grid_complianceShort-Circuit, Earthing, Lightning, TRV & HV PhysicsHV Substation Physics: Altitude Dielectric Scaling, Busbar Electrodynamics, Earthing & Grid EnvelopeYou compute altitude air-density dielectric scaling, geometric air clearances, creepage distance, Biot-Savart busbar short-circuit forces, two-layer soil earthing, electro-geometric lightning interception, or per-unit U/f/Q grid envelopes.
brain_calc_transformer_ecodesign_dgaTransformers, Protection Physics, SI Flash & WaveformsTransformer: PEI Efficiency, No-Load/Load Losses, 30-Yr TCO, Acoustics & DGA PhysicsYou evaluate P0/Pk losses, Peak Efficiency Index PEI, 30-year TCO, Maekawa acoustic barrier attenuation, or dissolved-gas diagnostics.
brain_calc_transformer_inrushTransformers, Protection Physics, SI Flash & WaveformsTransformer Magnetizing Inrush & Through-Fault Decay PhysicsYou specify `powerKva`, `primaryVoltageKv`, `secondaryVoltageV`, and `uccPercent`.
brain_calc_selectivity_tccTransformers, Protection Physics, SI Flash & WaveformsTime-Current Coordination (TCC) & Analytical Grading MarginsYou compare `upstreamRelay` and `downstreamRelay` (inverse-time family, pickupA, TMS) over `[ikMin, ikMax]`.
brain_audit_protection_physicsTransformers, Protection Physics, SI Flash & WaveformsProtection Physics Audit (CT Transient Ktd, ΔT Budget, Thermal Balance 49)You audit CT transient flux saturation (Kssc/Ktd), physical ΔT grading budget, and first-order thermal heating.
brain_calc_hv_protection_21_87tTransformers, Protection Physics, SI Flash & WaveformsHV Distance Impedance Zones Z1..Z4 & OLTC Differential PhysicsYou compute generic impedance distance zones Z1..Z4 (kZ0, load/SI resistance) and differential stability across OLTC tap range.
brain_calc_homopolar_67nTransformers, Protection Physics, SI Flash & WaveformsZero-Sequence Capacitive Return 3Ic0 & Directional Phasor CorridorYou audit MV capacitive sympathy currents 3Ic0 and evaluate directional phase-angle sectors.
brain_calc_arc_flash_ct_comtradeTransformers, Protection Physics, SI Flash & WaveformsSI Flash Incident Energy, RK4 CT Saturation & Transient WaveformsYou compute thermal incident energy in an enclosure SI fault, RK4 transient CT flux saturation, or asymmetric fault waveforms.
brain_calc_power_harmonicsPower Quality, Harmonics & Varmetric BalanceHarmonic Spectrum Physics, Eddy Factor K / F_HL & RLC ResonanceYou audit a harmonic spectrum, eddy-current transformer derating F_HL/K, and detuned + active filter resonance.
brain_calc_reactive_varmetricPower Quality, Harmonics & Varmetric BalanceVarmetric tan phi Balance, L_choc Inrush, P-Q Diagram & Sag PhysicsYou evaluate PCC tan phi reactive balance, back-to-back L_choc capacitor transients, generator P-Q capability, or sag propagation.
brain_calc_system_reliabilityMarkov Reliability, Critical Auxiliaries, Foundations & SI UnitsMarkov System Reliability Physics (Availability, Nines & VoLL)You evaluate availability of a series, parallel, open-loop, or k-out-of-n redundancy topology.
brain_calc_critical_power_safetyMarkov Reliability, Critical Auxiliaries, Foundations & SI UnitsCritical Power & Auxiliaries Physics (Gensets, UPS, H2 Dilution, EMC, Pit, PUE)You run auxiliary physics solvers (altitude genset derating, UPS/STS transfer, Faraday H2 ventilation airflow, EMC spacing, oil/fire-water retention, PUE).
brain_convert_electrotech_unitsMarkov Reliability, Critical Auxiliaries, Foundations & SI UnitsElectrotechnical Unit Conversion & Auto-ScalingYou convert an electrical quantity (`VA/kVA/MVA`, `W/kW/MW`, `var/kvar/Mvar`, `A/kA`, `V/kV`, `mOhm/Ohm`).
brain_calc_civil_concrete_foundationMarkov Reliability, Critical Auxiliaries, Foundations & SI UnitsGeotechnical Bearing, Reinforced Concrete & Anchor Physics (SI Model)You design or audit a reinforced concrete foundation (Meyerhof/Menard bearing, flexural/shear/punching concrete balance, anchor breakout/blow-out, and cover).
brain_calc_fm_global_fire_smoke_gisMarkov Reliability, Critical Auxiliaries, Foundations & SI UnitsTransformer Fire Separation, Deluge, Smoke HVAC & GIS/SF6 Safety (SI)You evaluate transformer thermal separation clearances, deluge spray (10.2 / 6.1 L/min/m2), retention volume, smoke/thermal airflow (vol/h, Pa), aspirating detection, and SF6/O2 room safety.
brain_audit_gis_mv_room_air_sf6Markov Reliability, Critical Auxiliaries, Foundations & SI UnitsGIS / MV SF6 Switchroom Audit: Free Air, O2, Purge & SI Overpressure (SI)You audit a GIS hall or MV SF6 switchroom: gross/net area, aisles, free air volume, homogeneous vs low-layer/trench SF6, residual O2, low-point purge t_95%, smoke extraction, and SI overpressure.
brain_calc_oil_containment_and_drain_hydraulicsMarkov Reliability, Critical Auxiliaries, Foundations & SI UnitsOil Containment, Manning Gravity Drain & Uplift Stability (SI)You size remote oil-water-rainfall containment with crushed-stone void deduction, select circular gravity collector pipes via Manning-Strickler, and check buoyancy uplift.
brain_calc_heavy_convoy_swept_path_craneMarkov Reliability, Critical Auxiliaries, Foundations & SI UnitsHeavy Convoy Swept Path, Gate Margin & Crane Bearing Solver (SI)You check heavy transformer multi-axle convoy dimensions, turning swept-path corridor width, gate opening margin, and crane outrigger timber mat ground bearing stress.